1

Stock

Required. Not inferred, defaulted or suggested.

2

Target

Form

The unit of every target above, whichever form is used.

3

Volume and route

What the stated volume is the volume of

Every option describes pipetted volumes. Volumetric preparation (diluent added to a mark) is out of scope.

4

Diluent

5

Pipetting capability

suggested, not chosen: 2 µL. Replace it with your pipette's value.

Nothing entered here is stored or transmitted. Reloading the page clears every field.

About this calculator

What it does

This tool works out the volumes to combine to reach a target concentration, or an ordered set of them, from a stock of known concentration. Where a step needs a transfer too small to pipette at your declared minimum, it plans one intermediate dilution. It plans the preparation; it does not check what was prepared.

How to use it

  1. Stock. Enter the stock concentration and its unit, and choose where that value came from (certificate of analysis, vendor datasheet, measured, computed by another Ligant tool, or not recorded). The source is printed with the plan; "not recorded" raises FL-04. Optionally enter the stock volume you have, which raises FL-06 if the plan needs more, and the stock formulation, which is recorded and not assessed.
  2. Target. Enter a single concentration, a list in the order you will prepare it, or a top concentration with a dilution factor and a number of points. The factor is final volume ÷ stock volume, so 1:100 (1 part stock in 100 parts total) is 100. Some labs write 1 part stock plus 99 parts diluent as "1:99"; that is also a factor of 100 here. In a serial chain each target must be lower than the one before; 0 is a diluent-only control.
  3. Volume and route. Enter one preparation volume, applied to every point, and say what it is the volume of: the final volume in each vessel, the diluent pipetted into each vessel, or (serial route only) the volume left in each vessel after the transfer to the next point. If you know how much you want in each tube, choose final volume. With more than one point, say whether each point is made from the previous one (serial) or from the stock (independent).
  4. Diluent. Enter the diluent, or tick "not recorded" (which raises FL-10). It is recorded, not assessed.
  5. Pipetting capability. Enter the smallest volume you can pipette reliably. The 2 µL shown is a suggestion; replace it with your pipette's value. Optionally enter the largest single transfer and the working capacity of your vessels; plans that exceed them are flagged.
  6. Read the plan. Each vessel lists what to add, in order, and its total. Beside each target you see the exact concentration, the achieved concentration the displayed volumes actually make, and the bound on the departure between them. If a flag appears, find its code in the table below. If the plan is withheld, the message says what to change.
  7. Copy the result. "Copy for notebook" copies the plan with every declaration, the engine version and every flag. "Print bench sheet" prints the same plan for the bench.

How it works

For each target the tool takes the dilution factor from its source (the stock, or the previous vessel in a serial chain): f = csource ÷ ctarget. A transfer T of the source into a vessel with diluent D gives ctarget = csource × T ÷ (T + D), so f = (T + D) ÷ T. What you stated as the preparation volume fixes the rest. Under the final-volume basis, T = F ÷ f and D = F − T. Under the diluent-volume basis, T = D ÷ (f − 1). Under the available-volume basis, each vessel is sized backwards from the last point so that the stated volume remains after the transfer to the next. The stated volume is a volume of solution under the final-volume and available-volume bases and a volume of diluent under the diluent-volume basis. Every basis describes pipetted volumes: the tool does not plan volumetric preparation in which the diluent is added to a mark.

Under the diluent-volume basis a step factor close to 1 requires a transfer many times the stated volume: the transfer into a vessel is D/(f − 1), which is unbounded by the stated volume as the step factor approaches 1.

Volumes are displayed to 3 significant figures, so a plan can carry up to about 1% rounding error per step before any pipetting error. That is larger than most users expect, and it is why the achieved concentration is shown beside every target: it is the concentration the displayed volumes make, and the bound on its departure from the target is computed from those volumes and stated at that point.

Intermediate selection rule

  1. For a step from a source at concentration cₐ (the stock, or the preceding vessel in serial mode) to a point b with factor f = cₐ/cᵦ whose direct transfer, as displayed, falls below the declared minimum m:
  2. Let Tᵦ(g) be the transfer into vessel b at the remaining factor f/g under the declared basis: F·g/f (final volume); D·g/(f − g) (diluent volume); Vᵦ·g/f with Vᵦ the backward-solved total of b (volume available after onward transfer). Each is increasing in g.
  3. Take the smallest g from the series {10, 100, 1000, …} with g < f such that (i) Tᵦ(g) ≥ m and, under the final-volume and available-volume bases, Tᵦ(g) ≤ Vᵦ − m, so that the destination holds at least the minimum of both the transfer and its derived diluent (under the diluent-volume basis the destination's diluent is the stated D, checked once against the declared minimum, and (i) keeps only its lower bound); (iii) where a capacity C is declared, the intermediate's total ≤ C; and, in serial mode, (iv) the intermediate's transfer from its source does not exceed the source vessel's total.
  4. Size the intermediate as max(g·m, the sum of every onward transfer taken from it). Its own transfer from its source is then at or above m by construction.
  5. In serial mode the intermediate sits between the source and b; the source's onward transfer is to the intermediate. In independent mode every point requiring the same g shares one intermediate, sized over all of them, and each such point is recorded as drawn from it.
  6. If no g satisfies these conditions the plan is rejected naming the bound that failed; a second intermediate is never chained.
  7. Every comparison with the minimum uses the displayed volume, the volume the bench sets.

Under the final-volume and available-volume bases no intermediate exists for a step with f ≤ 11: for f ≤ 10 the intermediate would be the point itself (the series floor), and for 10 < f ≤ 11 the destination cannot hold at least the minimum of both the transfer and its diluent while the direct transfer is below the minimum (the destination diluent bound). Under the diluent-volume basis the destination's diluent is the stated volume, the second case does not arise, and the floor is f ≤ 10. In every case the step is rejected, naming the bound that failed (the series floor and the destination diluent bound are named differently), and the remedy is the stated volume, not an intermediate. No value is recommended.

Constants and assumptions

NameValueWhy
Volume additivityaqueous stock and diluent; any co-solvent (glycerol, DMSO, ethanol) below about 5% v/v after mixing; cell suspensions treated as liquidMixing dilute aqueous buffers changes the total volume by less than 0.1 %, below the display rounding of almost every volume. Cases outside this scope are listed under "What it does not do".
Minimum reliable transfer volumedeclared by you; 2 µL suggestedIt applies to every pipetted volume, diluent included, and every comparison uses the displayed volume.
Intermediate factor series{10, 100, 1000, …}The series can be checked by eye.
Displayed precision, volumes3 significant figuresIt matches the resolution of the pipetting act the number drives.
Displayed precision, concentrations6 significant figuresA concentration drives a record, not a pipetting act, so it carries more figures.
Achieved-concentration boundat most 1.01 × 10⁻² per step; 5.03 × 10⁻³ where closure is exact or under the diluent-volume basisDerived analytically from the half-unit rounding of each displayed volume, compounded along the chain.
Closure residual±½ unit in the last displayed place of the one derived volume per vessel; zero under the diluent-volume basisUnder the final-volume and available-volume bases one volume in each vessel is worked out from the others and then rounded for display, so the displayed volumes can add up to the stated volume plus or minus half a unit in the last displayed place. Under the diluent-volume basis the total is not fixed in advance, so there is nothing to close.
Round-trip tolerance, exact concentration6 ULP of the target per step from stockA check on the arithmetic, not on your pipetting: recomputing each concentration from the unrounded volumes returns the target to within 6 units in the last binary place per step (about 1 part in 10¹⁵ or less), the most the rounding operations in each basis can produce.

Precision, rounding and engine version

Rounding is half away from zero, applied to the exact binary value. Every reported total and remaining volume is a sum or difference of displayed values and is never rounded. The unrounded values are carried in the result object. Every constant and threshold the tool applies also travels in the structured result beside the plan, generated by the same calculation that produced the plan. The source is at github.com/Ligant-AI/C3-Dilution-Planner.

Engine 1.2.3. The version changes whenever the calculation changes, so two results with the same engine version come from the same arithmetic.

Flags

A flag means the plan is printed but something needs your attention before you carry it out. FL-02, FL-03 and FL-06 mean the plan exceeds a maximum you declared; follow the flag's action first. Each flag appears beside the vessel or plan it concerns, with its code.

CodeWhat it meansWhat to do
FL-01An intermediate dilution was planned for a step whose direct transfer is below your declared minimum.Prepare the intermediate first, in the order shown, and draw the point from it.
FL-02A transfer is larger than the maximum single transfer you declared. Checked only if you declared a maximum.Split it into two or more transfers, or use a pipette with a larger maximum and declare that maximum.
FL-03A vessel would hold more than the working capacity you declared. Checked only if you declared a capacity.Use a larger vessel or a smaller stated volume.
FL-04The source of the stock concentration was recorded as "not recorded".The plan cannot be traced to a source. Record one before the plan goes into a method record.
FL-05The stated volume is a volume of diluent, so each diluted vessel ends up larger than the stated volume by the transfer. An undiluted point (target = stock) is the stated volume of stock, and a zero point is the stated volume of diluent.Use the final volume printed for each vessel, not the stated volume.
FL-06The plan needs more stock than the available volume you declared. Checked only if you declared an available volume.Reduce the stated volume or the number of points, or get more stock. A serial route usually needs less stock than independent points, at the cost of carrying each step's error into the next.
FL-07A flag raised by the tool that produced an imported value, restated with that tool named. Not raised in this release, which has no import.Read it as the origin tool states it.
FL-08A zero-concentration point is diluent alone and contains none of the stock.Prepare it separately from the chain.
FL-09A point equal to the stock concentration is undiluted stock; no diluent is added.Use the stock itself for that point.
FL-10The diluent was recorded as "not recorded".A concentration in an unrecorded diluent cannot be carried into a method record. Record the diluent.

When a plan cannot be carried out as stated, the tool withholds it and names every reason, rather than printing a plan with a warning.

  • The stock concentration is zero or negative.
  • A target concentration is negative.
  • A target is above the stock concentration; dilution cannot raise a concentration.
  • The stated volume is zero.
  • The dilution factor is 1 or below. A factor below 1 usually means it was entered as a fraction (0.01 for 1:100); enter it as final volume ÷ stock volume (100).
  • A transfer would take more than the donating vessel holds.
  • A serial chain does not decrease from one point to the next.
  • The stock and a target are in different kinds of unit (mass and molar). Converting needs a molecular weight, which this tool does not apply.
  • A step needs a transfer below your minimum, and no intermediate in the series can make it pipettable. The message names the bound that failed.
  • A diluent volume in the plan is below your minimum reliable transfer volume, so it cannot be pipetted as stated.

Why not a spreadsheet?

A dilution is arithmetic a spreadsheet performs correctly and records incompletely. What the stated volume is the volume of, whether the series was prepared serially or independently and from which vessel, and whether the plan is preparable at all are invisible in the resulting numbers. This tool asks for all three and puts them in the result.

  • Every assumption is a recorded choice. The basis of the stated volume, the route, the source vessel of each point, the diluent, the source of the stock value and the minimum transfer are asked for and printed with the plan, not left in a hidden cell.
  • Units are carried and checked. Results are shown in the unit you entered, and a stock in mass units with a target in molar units is refused rather than silently mixed.
  • Rounding is stated and bounded. Volumes are rounded once, to 3 significant figures, from the exact values; the unrounded values travel in the result, and the concentration the displayed volumes actually make is shown beside every target with its bound.
  • Flags say in words what to check, and a plan the bench cannot carry out is withheld with the reason, instead of being printed beside a warning. A needed intermediate dilution is planned for you.
  • The same inputs always give the same output, and the copy-out records every declaration, the engine version and every flag.

What it does not do

The tool guarantees that the plan's arithmetic is correct, that every volume to be pipetted in a printed plan is at or above your declared minimum, and that the volume basis, route, source vessel and provenance are recorded. A plan that exceeds a maximum transfer, vessel capacity or stock volume you declared is still printed, with FL-02, FL-03 or FL-06. It cannot detect:

  1. A stock concentration that is wrong: mislabelled, degraded, from a different lot, or correct for a different formulation.
  2. Incomplete mixing between serial steps. This is the largest real source of serial dilution error and is invisible in every record the tool produces.
  3. Adsorption of protein to vessel surfaces, significant at low concentrations without a carrier, which makes the achieved concentration lower than the planned one by an amount the tool cannot estimate.
  4. Departure from volume additivity outside the stated scope. Two cases are named: a stock in a co-solvent (glycerol, DMSO, ethanol) diluted at a low factor, where the co-solvent fraction after mixing exceeds about 5% v/v and the excess volume of mixing reaches 1–3%; and a dense suspension of large cells, where the cell volume fraction raises the free-solution concentration above nominal by 1–2%. The tool states the assumption and its scope; it cannot verify either.
  5. A pipette out of calibration. The declared minimum and maximum are statements of intent, not measurements of capability.
  6. Precipitation or instability at any concentration in the plan, including at an intermediate the tool itself introduced.
  7. Diluent incompatibility, which is recorded and not assessed.
  8. Any error in the execution of the plan. The tool states what to combine, and in what order; it does not observe what was combined.

Also outside its scope:

  • Mass ↔ molar conversion (Molarity Converter). Titration series design (Antibody Titration Planner). The direct per-point stock volume for a titration point that is already preparable (Antibody Titration Planner). Reconstitution of a dry solute (Reconstitution). Multi-component cocktails with overage (Master Mix).
  • Per-point stated volumes; volumetric (make-up-to-mark) preparation; plans needing more than one intermediate for a single step; mixing technique, incubation, temperature; diluent formulation or compatibility; carrier protein selection.

Entirely client-side: nothing entered into the planner leaves the browser. The newsletter signup in the footer is separate: only an email address you choose to submit there is sent. We use web analytics to count visits and see how quickly this page loads, so we can improve the tools, and further analytics only if you allow it in the banner. No analytics ever receives anything you type into this tool. No account. Nothing you enter persists across a reload.

Questions and answers

How do I plan a serial dilution from a stock concentration?

Enter the stock concentration and its unit, and choose where that value came from (certificate of analysis, vendor datasheet, measured, computed by the Molarity Converter, computed by Reconstitution, or not recorded; "not recorded" raises FL-04). Neither the value nor its unit is defaulted or suggested. Enter the target as a single concentration, a list in the order you will prepare it, or a top concentration with a dilution factor and a number of points, with its unit and where the target set came from. Enter one preparation volume, applied to every point, and say what it is the volume of. With more than one point, say whether each point is made from the previous one (serial) or from the stock (independent); a serial route usually needs less stock, at the cost of carrying each step's error into the next. Enter the diluent, or tick "not recorded" (which raises FL-10). Enter the smallest volume you can pipette reliably, replacing the 2 µL suggestion with your pipette's value. Optionally enter the stock volume you have, the largest single transfer and the working capacity of your vessels; plans that exceed them are flagged. Then read the plan: each vessel lists what to add, in order, and its total.

What does the volume I enter mean: final volume or diluent volume?

You choose one of three. Final volume is the sum of the diluent and the stock pipetted into each vessel. Diluent volume is the diluent pipetted into each vessel; the stock is added to it, so each diluted vessel ends up larger than the stated volume by the transfer, and the plan says to use the final volume printed for each vessel, not the stated volume (FL-05). Volume available after onward transfer is the volume that remains in each vessel once the transfer to the next point has been taken, and is available only for a serial route with more than one point. If you know how much you want in each tube, choose final volume. Every option describes pipetted volumes; volumetric preparation, with the diluent added to a mark, is out of scope.

Is a 1:100 dilution a factor of 100 or of 99?

In the top concentration, factor and count form, the factor is final volume ÷ stock volume, so 1:100 (1 part stock in 100 parts total) is 100. Some labs write 1 part stock plus 99 parts diluent as "1:99"; enter that as 100 too. A factor of 1 or below is refused: a factor below 1 usually means it was entered as a fraction (0.01 for 1:100); enter it as final volume ÷ stock volume (100). In a serial chain each target must be lower than the one before; 0 is a diluent-only control.

What happens when a volume to pipette is too small?

Where a step needs a transfer too small to pipette at your declared minimum, the tool plans one intermediate dilution (FL-01): prepare the intermediate first, in the order shown, and draw the point from it. The minimum is yours to declare; the 2 µL shown is a suggestion, so replace it with your pipette's value. For example, with a 10 mg/mL stock, a 0.01 mg/mL target, a final volume of 1000 µL and a 2 µL minimum, the direct transfer would be 1.00 µL, so the plan makes a 1 in 10 intermediate from 2.00 µL of stock and 18.0 µL of diluent, and draws 10.0 µL from it into 990 µL of diluent. The tool never chains a second intermediate: if no intermediate in the series 10, 100, 1000 and so on meets every bound (your minimum, any vessel capacity you declared and, in a serial chain, the volume in the vessel it is drawn from), the plan is withheld and the message names the bound that failed. A step that dilutes 10-fold or less (11-fold or less under the final-volume and available-volume bases) cannot take an intermediate at all; there the remedy is a larger stated volume.

Why is the achieved concentration different from my target?

Volumes are displayed to 3 significant figures, so a plan can carry up to about 1% rounding error per step before any pipetting error. That is larger than most users expect, and it is why the achieved concentration, the concentration the displayed volumes actually make, is shown beside every target, with the bound on the departure between them. Volumes are rounded once, from the exact values, and the unrounded values travel in the structured result.

Can I dilute a mass-concentration stock to a molar target?

No. A stock and a target in different kinds of unit, mass and molar, are refused, because converting needs a molecular weight, which this tool does not apply. For the stock and for every target, the units it accepts are mg/mL, µg/mL, ng/mL, g/L, mg/L, M, mM, µM, nM and pM; activity units such as IU/mL and U/mL are not among them. Converting between mass and molar is the Molarity Converter's job, for a protein whose molecular weight you declare; give the Dilution Planner a stock and targets in the same kind of unit.

What can go wrong that the planner cannot detect?

It does the arithmetic and records the volume basis, route, source vessel and provenance, but it cannot detect a stock concentration that is wrong (mislabeled, degraded, from a different lot, or correct for a different formulation); incomplete mixing between serial steps, which is the largest real source of serial dilution error; adsorption of protein to vessel surfaces, significant at low concentrations without a carrier, which makes the achieved concentration lower than the planned one by an amount the tool cannot estimate; a pipette out of calibration, because the declared minimum and maximum are statements of intent, not measurements of capability; precipitation or instability at any concentration in the plan, including at an intermediate the tool itself introduced; diluent incompatibility, which is recorded and not assessed; or departure from volume additivity outside its stated scope: a co-solvent (glycerol, DMSO, ethanol) above about 5% v/v after mixing, or a dense suspension of large cells, where the cell volume fraction raises the free-solution concentration above nominal by 1 to 2%. It states what to combine, and in what order; it does not observe what was combined.

Is my data uploaded anywhere?

No. Calculations run entirely in your browser, and your inputs are never transmitted, stored, or logged. The page sends an email address only if you choose to submit one in the newsletter signup, and its web analytics counts visits and sees how quickly the page loads, with further analytics only if you allow it in the banner; no analytics ever receives anything you type into this tool.

Is it free?

Yes. It is free to use and open source under the Apache 2.0 licence. Its source code is on GitHub, so you can download it and run it on your own computer.

The plan